Clinical Application of Color Doppler Ultrasonography Examinations in Diagnosis of Neonatal Pulmonary Hyaline Membrane Diseases

TANG Su-qiong1a, LI Bin1b,LIU Dan1a, HU Fen1a,HUANG Hua-ming2,ZHANG Jing-yu2, XU Yu-dong2

China Medical Devices ›› 2016, Vol. 31 ›› Issue (12) : 69-72.

PDF(2032 KB)
PDF(2032 KB)
China Medical Devices ›› 2016, Vol. 31 ›› Issue (12) : 69-72. DOI: 10.3969/j.issn.1674-1633.2016.12.017
CLINICAL IMAGING TECHNOLOGY

Clinical Application of Color Doppler Ultrasonography Examinations in Diagnosis of Neonatal Pulmonary Hyaline Membrane Diseases

  • TANG Su-qiong1a, LI Bin1b,LIU Dan1a, HU Fen1a,HUANG Hua-ming2,ZHANG Jing-yu2, XU Yu-dong2
Author information +
History +

Abstract

Objective To compare the plain X-ray radiography and lung ultrasonography examinations in diagnosis of the newborn hyaline membrane disease (HMD). Methods The X-ray and ultrasonic diagnosis of the lung of the 78 neonates that were suspected to the HMD were carried and then the results were analyzed. Meanwhile, the detection rate of the complications was analyzed by using the statistics. Results The results of the X ray showed that 15 HMD was the first level, 39 HMD was the second level, 18 HMD was the third level and 6 HMD was the fourth level. The results of the lung ultrasonic diagnosis showed that the lung consolidation and air bronchogram could be seen in the lung ultrasonography. The A line abolition, pleural abnormalities, pneumonedema and alveolus-mesenchymal syndromes were found in the 56 HMD. The pulmonary smooth disappearance and lung beat were found in the 24 HMD. The lung beat were not found in the 3 Second level HMD. The different level pleural effusion was found in the 5 HMD. The complications detection rate of the hyperacoustic group was higher than the X-ray group and the results were statistical significance (P<0.05). Conclusion The lung ultrasonography is a new way for the diagnosis of the HMD. It is featured with the advantages of usefulness, convenience, non-invasion and repeatability in examinations. The detection rate of the complications with the ultrasonography surpasses the X-ray.

Key words

hyperacoustic / hyaline membrane disease of newborn / premature birth / X-ray

Cite this article

Download Citations
TANG Su-qionga, LI Binb, LIU Dana, et al. Clinical Application of Color Doppler Ultrasonography Examinations in Diagnosis of Neonatal Pulmonary Hyaline Membrane Diseases[J]. China Medical Devices, 2016, 31(12): 69-72 https://doi.org/10.3969/j.issn.1674-1633.2016.12.017

References

[1] 黄晓玲,陈柏梁,房晓祎,等.INSURE策略治疗新生儿肺透明 膜病的临床疗效观察[J].中国临床研究,2014,27(4):457-458. [2] Boberk.Diagnostic utility of ultrasonography for respiratory distress syndrome in neonates[J].Med Sci Monit,2006,12(10):CR440- 446. [3] 徐国鸿.新生儿肺透明膜病例的X线诊断分析[J].医学理论与 实践,2014,27(8):1084-1085.
PDF(2032 KB)

778

Accesses

0

Citation

Detail

Sections
Recommended

/