Abstract:In this paper, through analyzing and reparing the common faults of of GETINGE 46-5 cleaning and disinfecting machine,
we provided reference maintenance experience for the same type of cleaning and disinfecting machine. Several malfunctions, such as
startup air switch overload protection, low circulating pump pressure, the temperature error of the cavity during the main washing, the
small impact force of the nozzle arm outlet hole, and the errors in the drying stage, were analyzed, and the corresponding solutions
were given. Through years of maintenance experience, based on the fault codes provided by the manufacturer, we summarized some
repair solutions when the equipments failed but fault codes were not reported, which would enriche the maintenance knowledge of
the equipment.
文涛. 瑞典GETINGE 46-5型清洗消毒机工作原理及故障维修[J]. 中国医疗设备, 2018, 33(12): 103-106.
WEN Tao. Working Principle and Troubleshooting of Swedish GETINGE 46-5 Cleaning and Disinfecting Machine. China Medical Devices, 2018, 33(12): 103-106.