Abstract:In this study, we introduced the testing performance of field electromagnetic compatibility tests for large medical equipment
medical hyperbaric chamber pressurized with air. Combined with the standards, the test method and test arrangement were studied. Besides,
the environmental noise influences of radiation emission, test location selection, test distance selection and immunity test method were
emphatically analyzed. Through analysis and research, a standardized test method with certain feasibility and reliability was gradually formed.
朱成科,李庆雨,刘美丽,徐志洲. 医用空气加压氧舱电磁兼容现场测试方法的研究[J]. 中国医疗设备, 2018, 33(11): 62-65.
ZHU Chengke, LI Qingyu, LIU Meili, XU Zhizhou. Study of EMC On-Site Test for Medical Hyperbaric Chamber Pressurized with Air Equipment. China Medical Devices, 2018, 33(11): 62-65.