Abstract:Objective To explore the values of clinical diagnosis in AECOPD with pneumothorax by lung ultrasound. Methods The
test results of chest CT, lung ultrasound and X ray for 52 cases of AECOPD with pneumothorax were observed. The sensibility,
specificity and precision of lung ultrasound and X ray were analyzed. Results The image analysis results in different severity of
pneumothorax assessment for three ways of checking were the same. There was no significant difference on the rate of AECOPD
with mild pneumothorax, moderate-severe pneumothorax, hydropneumothorax by chest CT, lung ultrasound and X ray (P>0.05).
The rate of missed diagnosis for lung ultrasound were lower than X ray (P<0.05). The sensibility, specificity and precision for lung
ultrasound were better than X ray, especially in mild pneumothorax checking (P<0.05). Conclusion The lung ultrasound is handled
easily with well accuracy. It is worthwhile to be used.
魏天虹,罗百灵,何志友. 肺脏超声在AECOPD气胸患者临床诊断中的价值[J]. 中国医疗设备, 2018, 33(5): 67-70.