Development and Application of Active Protection Type Triple Assembly Universal Matching Needles Threading Device
LIN Yang1, CHEN Zhi2, LI Yi3, CHU Min4, CHEN Yu-bo5, FANG Ke-heng6
1.School of Nursing, Xiamen Medical College, Xiamen Fujian 360123, China; 2.Department of Bone Traumatology, Xiamen Traditional Chinese Medicine Hospital, Xiamen Fujian 361009, China; 3.Department of First Orthopaedics, Jinjiang Hospital, Jinjiang Fujian 362200, China; 4.Department of Orthopaedics and Trauma tology, Fujiang University of Traditional Chinese Medicine, Fuzhou Fujian 350122, China; 5.Huisman (China), Zhangzhou Fujian 363105, China; 6.Department of Orthopaedics, Zhangpu Hospital, Zhangpu Fujian 363200, China
Abstract:To thread a needle efficiently and conveniently in poor conditions and special circumstances, the present study designed a multifunctional active protection universal matching type needle threading device through the human, universal, modular design and application. This device was consisted of a handle, a double-headed threading tool rest, a prober, a pair of auxiliary parts for screw driving. Three kinds of threading a needle device were designed integrate, where two modes of manual and pneumatic for threading a needle were coexisted. In addition, the cusps of the device was isolated completely and safely from the operator in the process of whole machinery operation. Two series of scalpel blade and tandem set of tool rests made up of a “three without” wildcard, with special effects of “triple dualmode, threading simultaneously, three full ranging and three free”. The characteristics of the triple universal matching type needles threading device, such as triple auxiliary threading needles, small and large scalpel slot through and universal matching, easy to install and remove, portable and easy to store, damage resistance and anti-lost, self-maintenance, safe and comfortable grip, repeat configuration and complementary good, low consume and environmental protection, universal in peacetime and wartime, high performance-price ratio made it helpful for decreasing human errors, raising efficiency to prevent the sharp instrument injuries, performing the implementation of patient safety objectives and the JCI certification standards for the details of management, as well as reducing the occupation harm risks and enhancing the quality and efficiency of operation and teaching.
林秧1,陈智2,李懿3,初敏4,陈宇博5,方克恒6. 主动防护型三联通配穿线纫针器的研制与应用[J]. 中国医疗设备, 2017, 32(1): 38-45.
LIN Yang1, CHEN Zhi2, LI Yi3, CHU Min4, CHEN Yu-bo5, FANG Ke-heng6. Development and Application of Active Protection Type Triple Assembly Universal Matching Needles Threading Device. China Medical Devices, 2017, 32(1): 38-45.