Abstract:Objective This study aimed to investigate the application of the self-produced steam in
the sterilization area of Central Sterile Supply Department, and to explore whether the self-produced
steam could contribute to the better implementation of the 24 hours sterilization system as well as to
the enhancement of the ability to provide apparatuses in urgent need. Methods The original centralized
supply was replaced by the self-produced steam in sterilization steam supply mode. Results The selfproduced
steam had more advantages over the centralized supply in the system management, equipment
management, supply time, and so on. The steam-sterilized water was in full compliance with the standard
of water. The application of the self-produced steam increased the qualification rate of sterilization,
ensured the qualification rate of BD test and batch, and enhanced the security ability. The comparison of
the data of two groups indicated that there were significant differences (P<0.05), which was statistically
important. Conclusion The self-produced steam not only can improve the steam quality and the
sterilization effect, but also can enhance the ability to provide material supply in our department.
庹琨明,赵卫萍,孟玲,杨涛,
李环. 蒸汽发生器在消毒供应中心的应用实践[J]. 中国医疗设备, 2016, 31(2): 135-137.
TUO Kun-ming,
ZHAO Wei-ping, MENG Ling,
YANG Tao, LI Huan. The Practical Application of the Self-Produced Steam in the
Sterilization Area of the Central Sterile Supply Department. China Medical Devices, 2016, 31(2): 135-137.