Abstract:Stereotactic body radiation therapy (SBRT) derives naturally from stereotactic radiosurgery (SRS) technology and clinical application. Under very precise image guidance, SBRT delivers a very large dose to a well-defined target in a small number of fractions. Body gamma knife is an innovative radiotherapy device that was independently conceptualized and designed in China, which extends Gamma-beam therapy from head to body. For nearly fifteen years of technology development and clinical practice, body gamma knife has been following the traditional body frame positioning mode, whose lack of position precision prevents the knife’s widespread application as a SBRT equipment. However, in recent years, image guidance technique begins to be applied in body gamma knife, which would initiate a new phase for its standard SBRT practice. This paper mainly introduces the principles, methods, experiments and preliminary results of an image-guided positioning system used in Body Gamma Knife.
付东山,黎维娟. 体部伽玛刀图像引导技术的发展[J]. 中国医疗设备, 2014, 29(10): 4-8.
FU Dong-shan, LI Wei-juan. Development of Image Guidance Techniques of Body Gamma Knife. China Medical Devices, 2014, 29(10): 4-8.
YinFF,Ryu S,Ajlouni M,et al.A technique of intensity-modulated radiosurgery (IMRS) for spinal tumors[J].Medical Physics,2002,29(12):2815-2822.
[3]
Benedick SH,Yenice KM,Followill D,et al.Stereotactic body radiation therapy:The report of AAPM Task Group 101[J]. Medical Physics,2010,37(8):4078-4101.
[9]
Leksell L.Stereotactic radiosurgery[J].Journal of Neurology, Neurosurgery & Psychiatry,1983,46:797-803.
[1]
Xing L,Thorndyke B,Schreibmann E,et al.Overview of image-guided radiation therapy[J].Medical Dosimetry,2006,31(2):91-112.
[2]
Potters L,Kavanagh B,Galvin JM,et al.American Society for Therapeutic Radiology and Oncology (ASTRO) and American College of Radiology (ACR) practice guideline for the performance of stereotactic body radiation therapy[J].Int J Radiat Oncol Biol Phys,2010,76:326-332.
[5]
Martin A,Gaya A.Stereotactic body radiotherapy: a review[J].Clinical Oncology,2010,22(3):157-172.
[7]
Saw CB,Bao S,Li S.A review on the technical and dosimetric aspects of stereotactic body radiation therapy (SBRT) [J].Journal of Radiation Oncology,2012,1:317-322.
[10]
Adler JR Jr,Chang SD,Murphy MJ,et al.The Cyberknife:A Frameless Robotic System for Radiosurgery[J].Stereotactic Functional Neurosurgery,1997,69:1-4.
[13]
Coste-Manièreè,Olender D,Kilby W,et al.Robotic whole body stereotactic radiosurgery:Clinical advantages of the CyberKnife integrated system[J].Int J Med Robot Comput Assist Surg,2005,1:28-39.
[8]
Leksell L.The stereotactic method and radiosurgery of the brai[J].ActaChir.Scand,1951,102:316-319.
[11]
Adler JR Jr,Murphy MJ,Chang SD,et al.Image-guided robotic radiosurgery[J].Neurosurgery,1999,44:1299-1307.
[4]
Klein EE,Hanley J,Bayouth J,et al.Task Group 142 report: Quality assurance of medical accelerators[J].Medical Physics, 2009,36(9):4197-4212.
[6]
Tipton K,Launders JH,Inamdar R,et al.Stereotactic Body Radiation Therapy:Scope of the Literature[J].Annals of Internal Medicine,2011,154:737-745.
Murphy MJ,Balter J,Balter S,et al.The management of imaging dose during image-guided radiotherapy:report of the AAPM Task Group 75[J].Medical Physics,2007,34(10):4041-4063.
[15]
Yan H,Yin FF,JK.A phantom study on the positioning accuracy of the Novalis Body system[J].Medical Physics,2003,30(12):3052-3060.