电子内窥镜自动测漏器的研制

黄建勋,迟昆荣,黄燕尔

中国医疗设备 ›› 2014, Vol. 29 ›› Issue (11) : 121-123.

PDF(1454 KB)
PDF(1454 KB)
中国医疗设备 ›› 2014, Vol. 29 ›› Issue (11) : 121-123. DOI: 10.3969/j.issn.1674-1633.2014.11.041
临床工程

电子内窥镜自动测漏器的研制

  • 黄建勋,迟昆荣,黄燕尔
作者信息 +

Development of An Automatic Leakage Detector for Electronic Endoscope

  • HUANG Jian-xun, CHI Kun-rong, HUANG Yan-er
Author information +
文章历史 +

摘要

漏水测试是电子内窥镜重要却容易被忽略的保养检验工作。本文阐述了我院自行研制的内窥镜自动测漏器的研制过程。该测漏器主要由主控板、外接电源、增压气泵及配套管路组成,可以对内镜进行自动增压、计时,判断其是否漏气,实现了内镜测漏自动化,提高了内镜测漏率。实际应用证实其测漏结果与原厂测漏器的检测结果一致,具有较高的可靠性。

Abstract

As one of the important maintenance inspections of electronic endoscope, leakage detection would be easily overlooked. This paper describes the development process of a self-developed automatic leakage detector for electronic endoscope. The detector which is mainly composed of the main control board, external power source, supercharging pump and suitable pipeline can automatically implement the supercharging and timekeeping of electronic endoscope and judge whether air leakage exists in the electronic endoscope. Thus the automatic leakage detection of electronic endoscope has been implemented and the leakage detection rate of electronic endoscope has been improved. The application results show that the detection results of the self-developed leakage detector are in line with those of the original factory leakage detector, which indicates that the self-developed leakage detector owns hign reliability.

关键词

电子内窥镜 / 漏水测试 / 自动测漏器

Key words

electronic endoscope / leakage detection / automatic leakage detector

引用本文

导出引用
黄建勋, 迟昆荣, 黄燕尔. 电子内窥镜自动测漏器的研制[J]. 中国医疗设备, 2014, 29(11): 121-123 https://doi.org/10.3969/j.issn.1674-1633.2014.11.041
HUANG Jian-xun, CHI Kun-rong, HUANG Yan-er. Development of An Automatic Leakage Detector for Electronic Endoscope[J]. China Medical Devices, 2014, 29(11): 121-123 https://doi.org/10.3969/j.issn.1674-1633.2014.11.041
中图分类号: TH776+.1   

参考文献

[1] 陈基明,张连强,田晓东.电子内窥镜的使用和维护[J].中国医疗设备,2010,25(5):97-98.
[2] 曹兴.医用电子内镜的工作原理和使用维护[J].中国内镜杂志,2010,16(8):895-896.
[3] 梁永健.OLYMPUS内镜钳子管漏水分析与维修方法[J].中国医学装备,2009,6(6):55-56.
[4] 李晓东,姚翔.内窥镜测漏的重要性及方法[J].医疗装备, 2001,(11):47.
[5] 毛燕正.电子内窥镜的常见故障解析及防范措施[J].中国医疗设备,2013,28(6):144.
[6] 官丽梅,王维明,周洪军.医用内窥镜的清洗消毒灭菌[J].医疗装备,2009,(4):82.
[7] 梅海珠.测漏是延长电子胃肠镜使用寿命的唯一途径[J].医疗装备,2012,(4):64.
[8] 张楠.浅谈医用电子内窥镜的基本结构工作原理及日常维护[J].医疗装备,2013,(3):71.