Quality Control Research on Flow Velocity Accuracy and Performance Stability of Infusion Pump
HAN Qian1,2, CHEN An-yu1
1.College of Biomedical Engineering, Capital Medical University, Beijing 100069, China; 2.Department of Medical Equipment, Beijing Jishuitan Hospital, Beijing 100035, China
Abstract:Infusion pump is one kind of the commonly used equipment in the aspects of first-aid, treatment and nursing in hospitals. In this paper, the flow velocity accuracy and performance stability of six infusion pumps which are choosed as the test infusion objects are tested with Fluke IDA-4 PLUS testing equipment for infusion devices. Thus relevant staff can get a better understanding of the service condition and service effect of infusion pump to decease the clinical risks of infusion pump.
韩乾,陈安宇. 输液泵流速精度及设备稳定性的质控研究[J]. 中国医疗设备, 2014, 29(3): 59-62.