基于低频电场心内膜三维标测技术的实验研究 |
惠杰1,吴珍峰1,2,沈海东5,张勇5,卫小兵1,3,王小青1,4,蒋文平1 |
1.苏州大学附属第一医院 心内科,江苏 苏州 215006;2.常州市第二人民医院 心内科,江苏 常州 213000;3.金坛人民医院 心内科,江苏 常州 213200;4.常州市第一人民医院 心内科,江苏 常州 213000;5.上海宏桐实业有限公司,上海 200233 |
|
Investigation of Three-dimensional Mapping Techniques in Endocardium with Low-frequency Current Field |
HUI Jie1, WU Zhen-feng1,2, SHEN Hai-dong5, ZHANG Yong5, WEI Xiao-bing1,3, WANG Xiao-qing1,4, JIANG Wen-ping1 |
1. Department of Cardiology, the First Affiliated Hospital of Soochow University, Suzhou Jiangsu 215006, China; 2. Department of Cardiology, Changzhou No.2 People’s Hospital, Suzhou Jiangsu 213000, China; 3. Department of Cardiology, People’s Hospital of Jintan, Changzhou Jiangsu 213200, China; 4. Department of Cardiology, the First People’s Hospital of Changzhou, Changzhou Jiangsu 213200, China; 5. Shanghai Hotong Co.,Ltd., Shanghai 200233, China |
引用本文: |
惠杰,吴珍峰,沈海东,张勇,卫小兵,王小青,蒋文平. 基于低频电场心内膜三维标测技术的实验研究[J]. 中国医疗设备, 2013, 28(12): 36-39.
HUI Jie, WU Zhen-feng, SHEN Hai-dong, ZHANG Yong, WEI Xiao-bing, WANG Xiao-qing, JIANG Wen-ping. Investigation of Three-dimensional Mapping Techniques in Endocardium with Low-frequency Current Field. China Medical Devices, 2013, 28(12): 36-39.
|
|
|
|
链接本文: |
http://www.china-cmd.org/CN/10.3969/j.issn.1674-1633.2013.12.011 或 http://www.china-cmd.org/CN/Y2013/V28/I12/36 |
[12] |
陈红武,杨兵,陈明龙. EnSite-NavX三维标测系统及临床应用[J].中国心脏起搏与心电生理杂志,2008,4(22):301-304.
|
[10] |
Hindricks G,Kottkamp H.Simultaneous noncontact mapping of left atrium in patients with paroxysmal atrial fibrillation[J].Circulation, 2001,104(3):297-303.
|
[11] |
Dong JZ,Ma CS,Liu XP,et al.Clinical results of circumferential pulmonary vein linear ablation in 100 patients with atrial fibrillation[J].Zhonghua Xin Xue Guan Bing Za Zhi,2005,33(10):907-911.
|
[13] |
陈浩然.框形电极标测右房心动过速[J].中国介入心脏病杂志,2001,9(3):41-43.
|
[14] |
陆俊,杨翠微,方祖祥.一种用于心外膜动态标测三维仿真的方法[J].中国医疗器械杂志,2005,(2):84-86.
|
[15] |
吴珍峰,惠杰,卫小兵.内膜三维重建及系统导航定位精度的基础研究[J].心电学杂志,2010,29(3):220-222.
|
[1] |
Friedman PA.Novel mapping techniques for cardiac electrophysiology[J].Heart,2002,87(6):575-582.
|
[22] |
马长生,董建增,汤日波,等.三维标测指导下心房颤动环肺静脉线性消融的效果评价[J].中国实用内科杂志,2006,26(8):1242-1245.
|
[17] |
Michelucci A,Bartolini P,Calcagnini G,et al.Mapping the organization of atrialfibrillation with basketcatheters.PartII:regional pattern sin chronic patients[J].Pacing&Clinical Electrophysiology,2001,24(12):1089-1096.
|
[3] |
Kottkamp H,Hindricks G,Breithardt G,et al.Three-dimensional electromagnetic catheter technology:electroanatomical mapping of the right atrium and ablation of ectopic atrial tachycardia[J].J Cardiovasc Electrophysiology,1997,8(12):1332-1337.
|
[5] |
Schilling RJ,Davies DW,Peters NS.Feasibility of a noncontact catheter for endocardial mapping of human ventricular tachycardia[J].Circulation,1999,99(19):2543-2552.
|
[20] |
Sun H,Velipasaoglu EO,Wu DE,et al.Simultaneous multisite mapping of the right and the left atrialseptum in the canine intact beating heart[J].Circulation,1999,100(3):312-319.
|
[6] |
Kadish A,Hauck J,Pederson B,et al.Mapping of atrial activation with a noncontact, multielectrode catheter in dogs[J].Circulation, 1999,99(14):1906-1913.
|
[8] |
Hassaguerre M,Jas P,Shah DC,et al.Right and left atrial radiofrequency catheter therapy of paroxysmal atrial fibrillation[J].J Cardiovasc Electrophysiol,1996,7(12):1132-1144.
|
[23] |
Smeets J L MR,Timmermans C,Rodriguez L M,et al.Can ventricular tachycardia in the absence of structural heart disease be cured by radiofrequency catheter ablation[J].Eur Heart,1993,14(2):256-258.
|
[10] |
Hindricks G,Kottkamp H.Simultaneous noncontact mapping of left atrium in patients with paroxysmal atrial fibrillation[J].Circulation, 2001,104(3):297-303.
|
[25] |
赵晖.基于LabVIEW的除颤监护检测仪的开发[J].中国医疗设备,2012,27(4):28-31.
|
[11] |
Dong JZ,Ma CS,Liu XP,et al.Clinical results of circumferential pulmonary vein linear ablation in 100 patients with atrial fibrillation[J].Zhonghua Xin Xue Guan Bing Za Zhi,2005,33(10):907-911.
|
[14] |
陆俊,杨翠微,方祖祥.一种用于心外膜动态标测三维仿真的方法[J].中国医疗器械杂志,2005,(2):84-86.
|
[15] |
吴珍峰,惠杰,卫小兵.内膜三维重建及系统导航定位精度的基础研究[J].心电学杂志,2010,29(3):220-222.
|
[18] |
曹克将,朱莉.EnSite 3000 标测系统及其临床应用[J].中国心脏起博与心电生理杂志,2001,15(4):4-7.
|
[18] |
曹克将,朱莉.EnSite 3000 标测系统及其临床应用[J].中国心脏起博与心电生理杂志,2001,15(4):4-7.
|
[17] |
Michelucci A,Bartolini P,Calcagnini G,et al.Mapping the organization of atrialfibrillation with basketcatheters.PartII:regional pattern sin chronic patients[J].Pacing&Clinical Electrophysiology,2001,24(12):1089-1096.
|
[20] |
Sun H,Velipasaoglu EO,Wu DE,et al.Simultaneous multisite mapping of the right and the left atrialseptum in the canine intact beating heart[J].Circulation,1999,100(3):312-319.
|
[21] |
Pitscher HF,Berkovic A,Grumbrecht S,et al.Multielectrode basketcatheter mapping for human atrial fibrillation[J].Cardiovasc Electrophysiol,1998,9(6):48-56.
|
[22] |
马长生,董建增,汤日波,等.三维标测指导下心房颤动环肺静脉线性消融的效果评价[J].中国实用内科杂志,2006,26(8):1242-1245.
|
[16] |
Barbaro V,Bartolini P,Calcagnini G,et al.Mapping the organization of atrialfibrillation with basketcatheters. PartI:Vali-dation of a real-time algorithm[J].Pacing&Clinical Electrophysiology,2001,24(12):1082-1088.
|
[19] |
Zrenner B,Ndrepepa G,Schneider M,et al.Basket catheter-guided three-dimensional activation patterns construction and ablation of common type atrial flutter[J].Pacing&Clinical Electrophysiology,2000,23(9):1350-1358.
|
[16] |
Barbaro V,Bartolini P,Calcagnini G,et al.Mapping the organization of atrialfibrillation with basketcatheters. PartI:Vali-dation of a real-time algorithm[J].Pacing&Clinical Electrophysiology,2001,24(12):1082-1088.
|
[4] |
Nademanee K,Kosar EM.A nonfluoroscopic catheter-based mapping technique to ablate focal ventricular tachycardia[J].PACE,1998,21(7):1442-1447.
|
[7] |
Ventura R,Rostock T,Klemm HU,et al.Catheter ablation of common-type atrial flutter guided by three-dimensional right atrial geometry reconstruction and catheter tracking using cutaneous patches: a randomized prospective study[J].J Cardiovasc Electrophysiol,2004,15(10):1157-1161.
|
[9] |
Chen SA,Tai CT,Yu WC,et al.Right atrial focal atrial fibrillation:electrophysiologic characteristics and radiofrequency catheter ablation[J].J Cardiovasc Electrophysiol,1999,10(3):328-335.
|
[12] |
陈红武,杨兵,陈明龙. EnSite-NavX三维标测系统及临床应用[J].中国心脏起搏与心电生理杂志,2008,4(22):301-304.
|
[26] |
Elvan A,Pride HP,Eble JN,et al.Radiofrequency catheter ablation of the atria reduces inducibility and duration of atrial fibrillation in dogs[J].Circulation,1995,91(8):2235-2244.
|
[2] |
Shah DC,Jais P,Haissaguerre M,et al.Three-dimensional mapping of the common atrial flutter circuit in the right atrium[J].Circulation,1997,96(11):3904-3912.
|
[19] |
Zrenner B,Ndrepepa G,Schneider M,et al.Basket catheter-guided three-dimensional activation patterns construction and ablation of common type atrial flutter[J].Pacing&Clinical Electrophysiology,2000,23(9):1350-1358.
|
[21] |
Pitscher HF,Berkovic A,Grumbrecht S,et al.Multielectrode basketcatheter mapping for human atrial fibrillation[J].Cardiovasc Electrophysiol,1998,9(6):48-56.
|
[24] |
郭涛,肖践明,韩明华,等.起搏标测在心室内消融靶点定位中的应用[J].昆明医学院学报,2003,(1):32-35.
|
[13] |
陈浩然.框形电极标测右房心动过速[J].中国介入心脏病杂志,2001,9(3):41-43.
|
[24] |
郭涛,肖践明,韩明华,等.起搏标测在心室内消融靶点定位中的应用[J].昆明医学院学报,2003,(1):32-35.
|
[26] |
Elvan A,Pride HP,Eble JN,et al.Radiofrequency catheter ablation of the atria reduces inducibility and duration of atrial fibrillation in dogs[J].Circulation,1995,91(8):2235-2244.
|
[23] |
Smeets J L MR,Timmermans C,Rodriguez L M,et al.Can ventricular tachycardia in the absence of structural heart disease be cured by radiofrequency catheter ablation[J].Eur Heart,1993,14(2):256-258.
|
[25] |
赵晖.基于LabVIEW的除颤监护检测仪的开发[J].中国医疗设备,2012,27(4):28-31.
|
|
|
|