Clinical Application Value of Digital Tomosynthesis in Skeletal Imaging Diagnostics
XU Jing1,2,3, XIA Xiu-jie3a, TIAN Bao-fang3b, DENG Da-ping1
1. Institute of Radiation Medicine, Shandong Academy of Medical Sciences, Jinan Shandong 250062, China; 2.School of Medicine and Life Sciences, University of Jinan-Shandong Academy of Medical Sciences, Jinan Shandong 250022, China; 3.a.Department of Radiology; b.Department of Emergency Surgery, Jining No.1 People’s Hospital, Jining Shandong 272003, China
Abstract:Objective To investigate the application value of digital tomosynthesis (DTS) in skeletal imaging diagnostics. Methods 68 patients who could not be identified as fractures with general radiography in our hospital from August 2011 to February 2013 were selected. Then digital tomosynthesis and CT examination were employed to these patients. Results 66 patients (97.05%) were determined as occult fractures by DTS while 56 patients (82.35%) were determined as occult fractures by CT. There were significant differences between the two diagnostic methods on fracture decetion rate (P<0.05). The proportion of high-quality images obtained by DTS was 94.11% while that of high-quality images obtained by CT examination was 85.29%. There were significant differences between the two methods on the proportion of high-quality images (P<0.05). Conclusion DTS with high diagnostic accuracy, clear images and low radiation dose is worth to be promoted.
徐晶,夏秀杰,田宝方,邓大平. 数字断层融合技术在骨骼影像诊断中的临床应用价值[J]. 中国医疗设备, 2014, 29(7): 166-168.
XU Jing, XIA Xiu-jie, TIAN Bao-fang, DENG Da-ping. Clinical Application Value of Digital Tomosynthesis in Skeletal Imaging Diagnostics. China Medical Devices, 2014, 29(7): 166-168.
Sarka V,Shi C,Rassiah-Szegedi P,et al.The effect of a limited number of projections and reconstruction algorithms on the image quality of megavoltage digital tomosynthesis[J].J Appl Clin Med Phys,2009,10(3):2970.
James TD,McAdams HP,Song JW,et al.Digital tomosynthesis of the chest for lung nodule detection: interim sensitivity results from an ongoing NIH-sponsored trial[J].Med Phys,2008,35(6):2554-2557.
Gomi T,Hirano H,Umeda T.Evaluation of the X-ray digital linear tomosynthesis reconstruction processing method for metal artifact reduction[J].Comput Med Imaging Graph,2009,33(4):267-274.
[7]
Godfrey DJ,Rader A,Dobbins JT.Practical strategies for the clinical implementation of matrix inversion tomosynthesis (MITS)[J].Proc SPIE,2003,50(30):379-390.
[8]
Maravilla KR,Murry RC,Deck M,et al.Clinical application of digital tomosynthesis:a preliminary report[J].AJNR Am J Neuroradiol,1983,4(3):277-280.
[5]
田军,宋少娟.数字化体层摄影与诊断图谱[M].北京:人民卫生出版社,2012.
[9]
Grant DG.Tomosynthesis:a three-dimensional radiographic imaging technique[J].IEEE trans Biomed Eng,1972,19(1):20-28.
Mestrovic A,Nichol A,Clark BG,et al.Integration of on-line imaging, plan adaptation and radiation delivery: proof of concept using digital tomosynthesis[J].Phys Med Biol,2009,54(12):3803-3819.